Section 3
Preparing Communications
■ Setting the Controller Number Switches (SW1 and SW2)
Controller Numbers
It is necessary to be able to distinguish between ID Controller when more than one ID Controller is
connected to a single host device. Each ID Controller is assigned a controller number for this purpose.
The controller number is included in commands and responses for 1:N communications. Communica-
tions will not be possible if the controller numbers are not set correctly.
SW1 and SW2 are enabled when SW3 pin 1 is OFF (DIP switches enabled). If SW3 pin 1 is ON (internal settings
enabled), the controller numbers specified with the SP command are used.
Controller Number Switches
SW1
SW2
Upper
Lower
digit
digit
0
0
0
0
0
0
0
0
0
0
1
1
:
2
3
3
3
3
:
9
The controller number switches are factory-set to 00.
Do not set the controller number switches to between 32 and 99.