Controller
6.8 Parameters
Static opening force
This force is effective during the opening movement if an open command is present.
See also Figure 6-9 Current – force – motor characteristic in the opening and closing
directions (Page 81).
Adjustment ranges
The parameter can be adjusted in accordance with the adjustment ranges of the parameters
(see Section Profiles and adjustment ranges (Page 148)). The value of the parameter must
be selected so that the door moves across the entire door width in the opening direction if an
open command is present. Inadequate force can lead to an obstruction of the door.
Static closing force
This force is effective during the closing movement if a close command is present.
See also Figure 6-9 Current – force – motor characteristic in the opening and closing
directions (Page 81).
Adjustment ranges
The value of the parameter must be selected so that the door moves across the entire door
width in the closing direction if a close command is present. Inadequate force can lead to an
obstruction of the door.
The closing force can be adjusted in accordance with the adjustment ranges of the
parameters (see Section Profiles and adjustment ranges (Page 148)).
A warning appears on the digital display of the terminal module if the set closing force of
150 N is exceeded. The stated values refer to doors opening to one side. A load cell in the
middle of centrally opening doors would show only half the value.
Risk of injury and material damage due to excessive closing force of the door
When the closing force is set, it is imperative that any effective closing weight is taken into
account.
The desired closing force must be reduced by 10 N for each 1 kg of counterweight. This
affects the:
• Closing force CLOSE
• Closing force cutter distance CLOSE
• Nudge force CLOSE
Example: Closing weight = 4 kg
Desired static force limit CLOSE = 150 N
The counterweight of 4 kg corresponds to a force of 40 N. The force limit then has to be
adjusted to 150 N – 40 N = 110 N.
The factory setting is preconfigured for the following counterweight:
● 6 kg for the MED280 motor
This means that the force limit for the resulting static closing force is preset to 90 N.