Setting the closing forces
1. Press the learn run button (S401) to set the closing forces.
2. The LED display alternates between displaying an "A" and the currently set counterweight
in the form of a number from 0 to 6.
3. Select the desired counterweight (0 to 6) by pressing the service button S402
(downwards) or S403 (upwards).
Note
The closing forces are set in the form of a counterweight. The calculation uses the
simplified ratio of 1 kg to 10 N.
The input ranges from 0 to 6, where 0 stands for "no counterweight" and 6 for a "6 kg
counterweight".
The input of the counterweight changes the closing force, as it is subtracted from the
maximum value of 150 N. The setting "6" thus reduces the closing force to 90 N (150 N –
60 N = 90 N).
4. Confirm the closing force you have selected by pressing and holding down the learn run
button (S401) until the dot lights up on the LED display (> 2 seconds).
The dot on the LED display indicates that the settings have been stored successfully.
Note
If the learn run button (S401) is pressed only briefly, the minimal editor switches to the
profile setting menu. The newly set counterweight value is not saved.
Deactivating (exiting) the minimal editor
1. Disconnect the controller from the power supply by unplugging the power plug.
2. Connect the controller to the power supply by plugging in the power plug.
Note
The line voltage can alternatively be connected and disconnected with the X3 connector
directly on the controller.