Siemens SIDOOR ATE500E System Manual page 44

Automatic door controls, door drive
Hide thumbs Also See for SIDOOR ATE500E:
Table of Contents

Advertisement

Controller
6.4 Operation and parameter assignment
Learn run (when the supply voltage is applied)
Table 6- 3
Starting a learn run when the supply voltage is applied
Procedure
1.
Slide the door to the CLOSED position or use the service buttons OPEN (S402) / CLOSE (S403) to move
to the CLOSED position.
2.
Disconnect the power supply from X3 (DC).
3.
Press the learn run button (S401) and keep it pressed (up to 10 s).
4.
Connect the power supply to X3 (DC).
5.
The learn run starts automatically, and the learn run button can be released.
6.
During the learn run, the door is opened about 10 cm, and closed once or twice at creep speed to deter-
mine the CLOSED position.
The width of the door is then determined by opening and closing the door once at creep speed.
The door then opens and closes through its complete range of movement at a speed of up to 700 mm/s to
determine the weight of the door.
7.
The door parameters and the determined door width are saved when the door is in the CLOSED position.
This means that the door width and weight are re-adapted and saved. The standard parameters for energy
limitation, speed limitation and all other driving curve parameters are also loaded.
8.
Learn run completed.
The door is in the CLOSED position.
Learn run (during operation)
Table 6- 4
Starting a learn run during operation
Procedure
1.
Push the door into the CLOSED position or move it to the CLOSED position with the OPEN (S402) or
CLOSE (S403) service buttons.
2.
Press and hold down the learn run button (S401) for 3 s.
3.
The learn run starts automatically, and the learn run button can be released.
4.
During the learn run, the door is opened about 10 cm, and closed once or twice at creep speed to deter-
mine the CLOSED position.
The width of the door is then determined by opening and closing the door once at creep speed.
The door then opens and closes through its complete range of movement at a speed of 700 mm/s to de-
termine the weight of the door.
5.
The door parameters and the determined door width are saved when the door is in the CLOSED position.
This means that the door width, door weight, energy limitation and speed limitation are re-adapted and
saved.
6.
Learn run completed.
The door is in the CLOSED position.
44
System Manual, 09/2017, A5E33917696-AD
H401
display
H401
display
ATE500E

Advertisement

Table of Contents
loading