Power supply
8.2 SIDOOR NT40
Output line X2
X2 is the output line connecting to the SIDOOR controller.
Connections
Cable type
Cable length
Connector(s)
Short-circuit protection
Output X2 is short-circuit proof.
Dangerous electrical voltage
May cause death, serious injury or material damage.
The third line brought out at the output is a functional grounding connection. The functional
grounding connection must not be understood or used as grounding in the sense of a PE
connection!
110
WARNING
UA+, UA-, FE
H05RN-F 3G1
1.5 m
WAGO 721-103/026-045
System Manual, 09/2017, A5E33917696-AD