Service buttons OPEN and CLOSE
The OPEN (S402) and CLOSE (S403) service buttons can be used for the following
purposes:
● Positioning the door before the learn run
If the status code "_" or "P" is shown on the 7-segment display (H401), the door can be
positioned with the OPEN (S402) and CLOSE (S403) service buttons.
● Cancelation of a learn run
If the status code "H" is shown on the 7-Segment display (H401), an active learn run can
be canceled by pressing the OPEN (S402) or CLOSE (S403) service button.
A learn run can also be canceled by pressing the learn run button (S401) again.
Note
After a cancelled learn run changing over to normal operation is only possible through a
restart of the controller (disconnection from the supply voltage).
● Using the minimal editor
See Section Using the minimal editor (Page 46).
● Controlling the door
Door movements in the OPEN and CLOSE directions can also be made manually with
the service buttons S402 (OPEN) and S403 (CLOSE).
The OPEN and CLOSE service buttons have the highest command priority. Commands
entered via the digital inputs, serial interfaces or menu control are overridden by the
service buttons. Each of these service buttons has to be actuated until the door control
has detected the respective end position of the door.
If the OPEN and CLOSE buttons are pressed simultaneously or the OPEN and CLOSE
signals are present simultaneously, the door always moves in the OPEN direction.
ATE500E
System Manual, 09/2017, A5E33917696-AD
WARNING
Risk of injury during commissioning
Prior to the learn run, the "closed" and "open" positions are unknown. For this reason,
the direction of movement of the door resulting from pressing the OPEN (S402) or
CLOSE (S403) service buttons is dependent on the way that the door and motor have
been installed.
Increased forces arise in the opening and closing directions when positioning the door
using the OPEN (S402) and CLOSE (S403) service buttons, and before a learn run the
7-segment display (H401) shows the status code "_" or "P". The reversing unit is not
active. You must therefore ensure that the door is safely cordoned off.