Interface
The interface supports the CANopen protocol according to CiA 301, profile 417.
Note
The SIDOOR SERVICE TOOL must be used to set the command input to CAN, so that the
controller can be addressed via the CAN bus.
The factory settings of the major parameters are:
Parameter
Command input
CANopen node ID
Baud rate
Door number
When the baud rate is set to "automatic", the CAN module automatically determines the
baud rate on the CAN bus. To do this, the CAN module must have received some valid CAN
telegrams. The LED H3 flashes at 5 Hz (quick flashing) while the baud rate is being
automatically determined.
LED signals
All LED signals are listed in the following table.
LED signal (H3)
(1 x per second)
(1 x per second)
(∼5 Hz)
ATE500E
System Manual, 09/2017, A5E33917696-AD
Factory setting
Digital IO (digital inputs)
Note: Setting to CAN required!
7
Automatic
1
CANopen state machine
No CAN telegrams are received
"Pre-operational" or
"Stopped"
CAN telegrams are received
No CAN telegrams are received
"Operational"
CAN telegrams are received
Automatic determination of the baud rate
6.6 Connecting terminals and interfaces
Controller
73