LPOD C-/Ku-Band Outdoor Amplifier/Block Up Converter
Ethernet Management
4.5.5.3.4
Config | Redundancy
For detailed information about 1:1 Redundant operations, see Appendix A. 1:1
REDUNDANCY.
IMPORTANT
The 'Config | Redundancy' page (Figure 4-9) is used to configure the LPOD's Redundancy
Switch Mode.
Using the drop-down menu, select the Switch Mode as follows:
•
Off: Disables redundancy.
•
1:1 Red TX: Enables 1:1 redundancy with transmit switch control.
•
1:1 Red TX+RX: Enables 1:1 redundancy with transmit and receive switch control.
•
1:2 Red TX:
•
1:2 Red TX+RX:
•
Manual: Enables manual redundancy mode.
Once the desired mode selection has been made, click [Change] to execute the choice.
To force a unit to go active (online), click [Force Online].
To update the page to the current redundancy configuration, click [Refresh].
Figure 4-9. Config | Redundancy page
(Future option – not currently supported)
(Future option – not currently supported)
4–20
Revision 3
MN-LPOD