Comtech EF Data LPOD Hardware Installation And Operation Manual page 138

C-/ku-band outdoor amplifier/block up converter (buc)
Table of Contents

Advertisement

LPOD C- / Ku-Band Outdoor Amplifier/ Block Up Converter (BUC)
Appendix B
Command
(Instruction
Parameter Type
Code and
Qualifier)
Retrieve next 5
N/A
unread Stored
E
Alarms
Unit MAC
N/A
Address
Arguments for
Description of Arguments
Command or
(Note that all arguments are printable ASCII
Response to
Query
145 bytes
Query only.
The unit returns the five oldest stored events in the
alarm log, and if there are no events in the log the unit
will reply with LNA*. All events that are read from the
log are also automatically removed from the log.
Reply format:
YYYYYYYYYY ZZ mmddyy hhmmss'cr'
YYYYYYYYYY ZZ mmddyy hhmmss'cr'
YYYYYYYYYY ZZ mmddyy hhmmss'cr'
YYYYYYYYYY ZZ mmddyy hhmmss'cr'
YYYYYYYYYY ZZ mmddyy hhmmss'cr''lf'
Where:
YYYYYYYYYY is the fault description.
ZZ is one of the event types listed below:
FT = Fault
OK = Clear
IF = Information
The rest of the string is a date / time stamp.
Example: <1/LNA?'cr'
>0001/LNA='cr'
LOG CLR IF 175503 052307'cr'
FAN #1 FT 175504 052307'cr'
OVR TMP FT 175504 052307'cr'
FAN #1 OK 175504 052307'cr'
IIC BUS FT 175504 052307'cr''lf'
17 bytes
Query only.
MAC address of the unit, reported in hexadecimal.
Example: <1/MAC?'cr'
>0001/MAC=00-06-B0-00-D2-A7'cr''lf'
characters)
LNA=
MAC=
B–20
Query
Response to
(Instruction
Command
Code and
(Target to Controller)
qualifier)
LNA?
N/A
Revision 3
MN-LPOD
Response to
Query
(Target to
Controller)
LNA=YY..ss
(See Description
of Arguments for
details)
MAC=xx-xx-xx-
xx-xx-xx
(See Description
of Arguments for
details)

Advertisement

Table of Contents
loading

Table of Contents