LPOD C-/Ku-Band Outdoor Amplifier/Block Up Converter
Ethernet Management
AUX Mute: Using the drop-down menu, select the Auxiliary Mute Mode as either
Enabled or Disabled.
Attenuation Offset: Enter a valid value, in dB, for the attenuation offset.
Fault Recovery: Using the drop-down menu, select Fault Recovery as either Automatic or
Manual.
Once the desired configuration settings have been made in this section, the user should then click
[Change Configuration] to save these changes. If it is desired to revert back to the previously
assigned Amplifier settings, the user should instead click [Reset].
Reference
Ref Freq Adjust: Enter a numeric value from 0 to 255 to adjust the reference oscillator
tuning voltage. The default value is set to 87.
Ext Ref Mute: Using the drop-down menu, select the Eexternal Reference Not Present
Mute Mode as either Enabled or Disabled.
Once the desired configuration settings have been made in this section, the user should then click
[Change Configuration] to save these changes. If it is desired to revert back to the previously
assigned Reference settings, the user should instead click [Reset].
Low Power Forward Threshold (dBm)
Use this field to set the threshold value, in dBm, for the low forward power alarm/fault. If the
forward power drops below the specified value, the alarm/fault will be indicated if the forward
power monitor is set to Alarm or Fault instead of the factory default of Mask. Setting this
parameter to the default value of 00.00 effectively disables the threshold.
Once the desired configuration setting has been made in this section, the user should then click
[Change] to save this change.
To update the page appearance to the current operating configuration, click [Refresh].
4–16
Revision 3
MN-LPOD