Comtech EF Data LPOD Hardware Installation And Operation Manual page 132

C-/ku-band outdoor amplifier/block up converter (buc)
Table of Contents

Advertisement

LPOD C- / Ku-Band Outdoor Amplifier/ Block Up Converter (BUC)
Appendix B
Command
(Instruction
Parameter Type
Code and
Qualifier)
Concise
N/A
Maintenance
Status
LNB Current
CWE=
Window Enable
Arguments for
Description of Arguments
Command or
(Note that all arguments are printable ASCII
Response to
Query
95 bytes
Query only.
Used to Query the Maintenance status of the unit in a
concise format. The response is semicolon delimited.
This is the concise version of the RMS command.
Example: <1/CMS?
>0001/CMS=aaa.a;bbb.b;ccc.c;ddd.d;eee.e;fff.f;ggg.g;
hhh.h;iii.i;jjj.j;kkk.k;lll.l;mmm.m;nnn.n;ooo.o;ppp.p;qqq
rrr.r;sss.s;ttt.t'cr''lf', where:
aaa.a = P24V1
bbb.b = P24V2
ccc.c = LNBVT (see Note)
ddd.d = P13VT
eee.e=P10V1
fff.f = A10V1
ggg.g = A10V2 (see Note)
hhh.h = P7V8T
iii.i = P5V8T
jjj.j = P2V5T
kkk.k = P1V2T
lll.l = N5V8T
mmm.m = FANR1 (see Note)
nnn.n = FANR2 (see Note)
ooo.o = BUCVT (see Note)
ppp.p = FWPWR
qqq.q = REFVT (see Note)
rrr.r = LNBCS (see Note)
sss.s = ATEMP
ttt.t = OTEMP (see Note)
Note: ccc.c, ggg.g, mmm.m, nnn.n, ooo.o, qqq.q, rrr.r,
and ttt.t will appear if the appropriate model/options
have been selected/installed. Otherwise, the unused
fields will display XXXXX.
1 bytes
Command or Query.
This command allows the user to enable the current
window alarm. If disabled, the LCW value will be
retained, but unused.
Example: <1/CWE=0'cr'
>0001/CWE='cr''lf'
Default Value: 0
characters)
CMS=
.
q;
CWE =
CWE?
CWE *
B–14
Query
Response to
(Instruction
Command
Code and
(Target to Controller)
qualifier)
CMS?
CWE?
Revision 3
MN-LPOD
Response to
Query
(Target to
Controller)
CMS=x....x
(See Description
of Arguments for
details)
CWE =x
(Same format as
command
arguments)