Comtech EF Data LPOD Hardware Installation And Operation Manual page 134

C-/ku-band outdoor amplifier/block up converter (buc)
Table of Contents

Advertisement

LPOD C- / Ku-Band Outdoor Amplifier/ Block Up Converter (BUC)
Appendix B
Command
(Instruction
Parameter Type
Code and
Qualifier)
Enable
ESW=
Redundancy
Switch Mode
Retrieve
N/A
Firmware Number
Arguments for
Description of Arguments
Command or
(Note that all arguments are printable ASCII
Response to
Query
1 byte
Command or Query.
Turns ON or OFF the redundancy state, where:
0 = Off
1 = 1:1 Redundancy TX (Only TX switch installed)
2 = 1:1 Redundancy TX + RX (TX and RX switch
installed)
5 = 1:1 Manual redundancy mode (used for debugging,
or redundant system setup). Manual redundancy does
not support automatic switching, and the offline unit
will not poll the online unit to update its configuration.
Example: <1/ESW=1'cr'
>0001/ESW='cr''lf'
Default Value: 0
Query only
Returns the firmware type(s) loaded into the unit. The
firmware information is returned in the following format:
FW-AAAAAAA B.B.BB DD/MM/YY
Where:
FW-AAAAAAA = the firmware part number
B.B.BB = the version number
DD/MM/YY = Day/Month/Year firmware released
Example:
<1/FRW?'cr'
>0001/FRW=
Boot:
FW-0000082 0.0.1a 04/09/08
Bulk1:
FW-0000078 0.0.1a 04/09/08
FW-0000080 0.0.1a 04/09/08
FW-0000081 0.0.1a 04/09/08
Bulk2:
FW-0000078 0.0.1a 04/09/08
FW-0000080 0.0.1a 04/09/08
FW-0000081 0.0.1a 04/09/08
characters)
ESW=
ESW?
ESW *
FRW=
B–16
Query
Response to
(Instruction
Command
Code and
(Target to Controller)
qualifier)
ESW?
FRW?
Revision 3
MN-LPOD
Response to
Query
(Target to
Controller)
ESW=x
FRW={CR}Boot:{
CR}abc{CR}Bulki:
{CR}abc{CR}abc
(See Description
of Arguments for
details)

Advertisement

Table of Contents
loading

Table of Contents