Comtech EF Data LPOD Hardware Installation And Operation Manual page 125

C-/ku-band outdoor amplifier/block up converter (buc)
Table of Contents

Advertisement

LPOD C- / Ku-Band Outdoor Amplifier/ Block Up Converter (BUC)
Appendix B
B.2.4.6
Optional Message Arguments
Arguments are not required for all messages. Arguments are ASCII codes for any printable character.
B.2.4.7
End of Packet
Controller-to-Target: This is the 'Carriage Return' character (ASCII code 13).
Target-to-Controller: This is the two-character sequence 'Carriage Return' (ASCII code 13), and
'Line Feed' (ASCII code 10).
Both indicate the valid termination of a packet.
B.2.4.8
End-of-Life Commands
Certain commands/queries are being marked as End-of-Life (EOL). As noted in the format
E
<description>
Sect. 3.3), while these commands are fully supported in this product it is highly recommended
that the equivalent new commands be used for new implementations. The new commands will
generally follow the outdated commands:
EOL-designated
Command/Query (Page #)
CAA (3-10)
CUS (3-13)
DAT (3-15)
LNA (3-20)
RET (3-25)
RSN (3-28)
SFS (3-30)
TNA (3-31)
in the Parameter Type field (in the Remote Commands and Queries tables in
New Command/Query (Page #) / Comment
CAE (3-10)
Functionality not included in any other remote command/query
DAY (3-15)
RNE (3-27)
PNM (3-22)
New query provides more exact unit hardware information
SNO (3-30)
Functionality not included in any other remote command/query
TNE (3-31)
B–7
Revision 3
MN-LPOD