Comtech EF Data LPOD Hardware Installation And Operation Manual page 145

C-/ku-band outdoor amplifier/block up converter (buc)
Table of Contents

Advertisement

LPOD C- / Ku-Band Outdoor Amplifier/ Block Up Converter (BUC)
Appendix B
Command
(Instruction
Parameter Type
Code and
Qualifier)
Retrieve Next 5
N/A
unread stored
Events
Arguments for
Description of Arguments
Command or
(Note that all arguments are printable ASCII
Response to
Query
Query only.
75 bytes
Unit returns the oldest 5 Stored Events which have not yet been
read over the remote control.
Reply format: {CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}
Sub-body{CR}Sub-body,
where Sub-body= ABCCddmmyyhhmmss:
A being the fault/clear indicator.
F=Fault
C=Clear
I=Info
B being the fault type where:
1=Unit
2=RF
3=Log
CC is Fault Code numbers, as in RAS? or Info Code, which is:
0=Power Off
1=Power On
2=Log Cleared
3=Global Config Change
4=Redundancy Config Change
RAS fault codes map as follows:
1)
P24V1
2)
P24V2
3)
LNBVT
4)
P13VT
5)
A10V1
6)
A10V2
7)
10VPS
8)
P5V8T
9)
P2V5T
10)
P1V2T
11)
N5V8T
12)
P7V8T
13)
FANR1
14)
FANR2
15)
ATEMP
16)
SHTDN
17)
IICST
18)
FWPWR
19)
CHKSM
20)
FPGAD
21)
BUCLD
22)
REFLD
23)
LNBCS
24)
SWITC
If there are less than 5 events to be retrieved, the remaining
positions are padded with zeros.
If there are no new events, the response is RNE*.
A Global Config Change is defined as any time a command is
successfully executed. A query does not set the status change
flag. The status change flag is cleared after being read. No other
events toggle a status change.
characters)
RNE=
B–27
Query
Response to
(Instruction
Command
Code and
(Target to Controller)
qualifier)
RNE?
Revision 3
MN-LPOD
Response to
Query
(Target to
Controller)
RNE={CR}ABCC
ddmmyyhhmmss{
CR}ABCCddmmy
yhhmmss{CR}AB
CCddmmyyhhmm
ss{CR}ABCCddm
myyhhmmss{CR}
ABCCddmmyyhh
m
mss
(See Description
of Arguments for
details)

Advertisement

Table of Contents
loading