Comtech EF Data LPOD Hardware Installation And Operation Manual page 139

C-/ku-band outdoor amplifier/block up converter (buc)
Table of Contents

Advertisement

LPOD C- / Ku-Band Outdoor Amplifier/ Block Up Converter (BUC)
Appendix B
Command
(Instruction
Parameter Type
Code and
Qualifier)
Unit Alarm Mask
MSK=
Mute State
MUT=
Arguments for
Description of Arguments
Command or
(Note that all arguments are printable ASCII
Response to
Query
5 bytes
Command or Query.
Alarm mask conditions. If the mask value for a certain
parameter is set to fault then a fault condition will be
registered if specified hardware conditions are not met.
If the mask value is set to alarm then a fault condition
will only appear to be an alarm that will not trigger a
switchover in a redundant system. If the mask value is
set to masked then the fault will never be reported to
the user.
Form of: abcde
Where:
0 = Fault, 1 = Alarm, 2 = Masked
a = Low Forward RF Power
b = External Reference Lock detect
c = Fan Speed
d = LNB Current Detect
e = LNB 22V Power Supply
Example: <1/MSK=22111'cr'
>0001/MSK=1'cr''lf'
Default Value: 22111
1 byte
Command or Query.
Mute the unit, where:
0 = Disable (Not Muted)
1 = Enable (Muted)
2 = Unit muted due to AUX mute signal. This value is
only shown in the response to a query, and cannot be
given as a command. When MUT returns a 2 it
indicates that one of the "hardware" mute conditions is
present. For example an auxiliary mute could be
present if the auxiliary mute has been enabled, and
the signal to unmute the unit is not provided.
Additionally, certain faults can generate a hardware
mute such as the BUC lock detect, the LNB current
draw (if enabled by the user), or the LNB voltage (if
enabled by the user). If MUT returns an unexpected
value of 2 then check the active faults, and the status
of the auxiliary mute.
Example: <1/MUT=1'cr'
>0001/MUT=1'cr''lf'
Default Value: 1
characters)
MSK=
MSK?
MSK*
MUT=
MUT?
MUT*
B–21
Query
Response to
(Instruction
Command
Code and
(Target to Controller)
qualifier)
MSK?
MUT?
Revision 3
MN-LPOD
Response to
Query
(Target to
Controller)
MSK=abcde
(See Description
of Arguments for
details)
MUT=x
(Same format as
command
arguments)