Comtech EF Data LPOD Hardware Installation And Operation Manual page 141

C-/ku-band outdoor amplifier/block up converter (buc)
Table of Contents

Advertisement

LPOD C- / Ku-Band Outdoor Amplifier/ Block Up Converter (BUC)
Appendix B
Command
(Instruction
Parameter Type
Code and
Qualifier)
Retrieve Alarm
N/A
Status
Arguments for
Description of Arguments
Command or
(Note that all arguments are printable ASCII
Response to
Query
168 bytes
Query only.
Used to Query the Alarm status of the unit, where:
OK = no fault condition,
FT = faulted,
AL = alarm,
YS = Yes,
NO = No,
MS = masked.
Example:
<1/RAS?'cr'
>0001/RAS='cr'
P24V1=OK'cr'
P24V2=OK'cr'
LNBVT=OK'cr'
P13VT=OK'cr'
P10V1=OK'cr'
A10V1=OK'cr'
A10V2=OK'cr'
P7V8T=OK'cr'
P5V8T=OK'cr'
P2V5T=OK'cr'
P1V2T=OK'cr'
N5V8T=OK'cr'
FANR1=OK'cr'
FANR2=OK'cr'
ATEMP=OK'cr'
SHTDN=OK'cr'
IICST=OK'cr'
FWPWR=OK'cr'
CHKSM=OK'cr'
FPGAD=OK'cr'
BUCLD=OK'cr'
REFLD=OK'cr'
LNBCS=OK'cr'
SWITC=OK'cr'
RDLNK=OK'cr'
TRMST=YS'cr''lf' Terminal Status
Note: LNBVT, A10V1, A10V2, FANR1, FANR2,
BUCLD, REFLD, LNBCS, SWITC and RDLNK will only
appear in the list if the appropriate model / options
have been selected / installed.
characters)
+24V power supply
+24V switch pwr supply
+13/18V LNB power supply
+13.5V power supply
+10V power supply
+10V1 RF supply
+10V2 RF supply
+7.8V power supply
+5.8V power supply
+2.5V power supply
+1.2V power supply
-5.8V power supply
Fan 1 speed
Fan 2 speed
Amplifier temperature
Over-temp shutdown
I2C bus status
Forward power in dBm
Flash checksum
FPGA done status
BUC lock detect
Reference lock detect
LNB current status
Waveguide switch position status
Redundant link status
B–23
Query
Response to
(Instruction
Command
Code and
(Target to Controller)
qualifier)
RAS=
RAS?
Revision 3
MN-LPOD
Response to
Query
(Target to
Controller)
RAS=x....x
(See Description
of Arguments for
details)