Comtech EF Data LPOD Hardware Installation And Operation Manual page 131

C-/ku-band outdoor amplifier/block up converter (buc)
Table of Contents

Advertisement

LPOD C- / Ku-Band Outdoor Amplifier/ Block Up Converter (BUC)
Appendix B
Command
(Instruction
Parameter Type
Code and
Qualifier)
Calibrate LNB
CLC=
Current
Clear Statistics
CSL=
Log
Concise Utility
N/A
E
Status
Arguments for
Description of Arguments
Command or
(Note that all arguments are printable ASCII
Response to
Query
none
Command or Query.
The CLC command stores the value of the LNB Current
Supply (in mA) as a reference point. The LNB current
alarm point is then determined by the calibrated LNB
reference point, and the LNB current window setting
(see LCW command).
Note: this command will return a mode error if the LNB
current source output has not been enabled first (see
LCS command).
Example: <1/CLC='cr'
>0001/CLC='cr''lf'
The CLC query will return the value that was stored
during the LNB current calibration.
Example: <1/CLC?'cr'
>0001/CLC=xxx.x Where:
xxx.x is the calibrated LNB current value in mA.
Default Value: 000.0
1 byte
Command only.
Used to clear the statistics log entries.
Example:
<1/CSL=1'cr'
>0001/CSL='cr''lf'
15 bytes
Query only.
Used to Query the Maintenance status of the unit,
response is comma delimited.
Example:
<1/CUS?'cr'
>0001/CUS=aaaa;bbbbb;ccc;'cr''lf'
Where:
aaaa = Remote Unit Address
bbbbb = Remote Baud Rate
ccc = Reference oscillator tuning voltage DAC value
(See Note)
Note: ccc is only present if a reference oscillator is
installed.
characters)
CLC=
CLC?
CLC*
CSL=
CSL?
CSL*
CUS=
B–13
Query
Response to
(Instruction
Command
Code and
(Target to Controller)
qualifier)
CLC?
N/A
CUS?
Revision 3
MN-LPOD
Response to
Query
(Target to
Controller)
CLC=xxx.x
(See Description
of Arguments for
details)
CSL=
CUS=x....x
(See Description
of Arguments for
details)