Siemens SIMATIC S5-95F Manual page 510

Table of Contents

Advertisement

S5-95F
Relay Output Module 4 x 30 V DC/ 230 V AC
.0
.4
.1
.5
.2
.6
.3
.7
RELAY OUTPUT
4 x 30 V DC/230 V AC
6ES5 452-8MR11
1
2
3
4
5
1
3
5
2
4
L+
M
X.0
X.1
EWA 4NEB 812 6210-02
L+
1
M
2
3
4
5
6
7
8
9
10
7
6
+9 V
GND
Data
7
9
6
8
10
X.2
X.3
Technical Specifications
Outputs
Galvanic isolation
- in groups of
Continuous current I
th
Length of cable
- unshielded
max.
Rated insulation voltage
(+ 9 V to L 1)
- insulation group
- tested with
Rated insulation voltage
(+ 9 V to
)
- insulation group
- tested with
Current consumption
- from + 9 V (CPU)
typ.
- from L+
typ.
Power loss
of the module
typ.
Weight
approx. 240 g (8 oz.)
Switching capacity
of the contacts
- resistive load
max.
- inductive load
max.
Operating cycles of
the contacts according to
VDE 0660, part 200
- AC - 11
- DC - 11
Switching frequency
max.
Rated insulation voltage
(between contacts)
- insulation group
- tested with
Supply voltage L+
(for the relays)
- rated value
- ripple V
max.
PP
- permissible range
(ripple included)
- value at t <0.5 s
EMC Characteristics for Use in S5-95F
Electrostatic discharge
to IEC 801-2
tested with
Electromagnetic fields
to IEC 801-3
tested with
Fast transient burst
to IEC 801-4
tested with
Module Spectrum
(6ES5 452-8MR11)
4 relay outputs, contact
switching varistor
yes (optocoupler)
1
5 A
100 m (330 ft.)
250 V AC
2 x B
1500 V AC
12 V AC
1 x B
500 V AC
14 mA
100 mA
2 W
5 A at 250 V AC
2.5 A at 30 V DC
1.5 A at 250 V AC
0.5 A at 30 V DC
6
1.5 x 10
6
0.5 x 10
10 Hz
250 V AC
2 x B
1500 V AC
24 V DC
3.6 V
20 to 30 V
35 V
Severity rating 3
8 kV air discharge
6 kV contact
discharge
Severity rating 2
3 V / m
Severity rating 2
1.2 kV on supply lines
1 kV on signal lines
A-15