Siemens SIMATIC S5-95F Manual page 359

Table of Contents

Advertisement

S5-95F
Example:
The S5-95F is to be a slave with the slave number 2 on the SINEC L1 bus. Subunit A
is interfaced to the L1 bus:
The Send mailbox begins at data word 0 in DB2
The Receive mailbox begins at data word 10 in DB2
The Coordination Byte Send is flag byte 0
The Coordination Byte Receive is flag byte 2
The PG bus number is 1
Table 13-2 shows how to edit the default parameters for the example, and which parameter values
are permissible:
Table 13-2. Initializing the Interface for Non-Failsafe Data Interchange
Parameter in
Default DB1
...
SL1:
PGN N
(required to execute programmer
SLN N
Block ID: "Subunit A on SINEC
SL1A:
Location of the Send mailbox
SF N
Location of the Receive mailbox
EF N
Location of the "Coordination
KBE N
Location of the "Coordination
KBS N
*
The KBE/KBS is in the high-order byte of the specified data word.
EWA 4NEB 812 6210-02
Description
Block ID: "SINEC L1"
Programmer bus number
functions over the L1 bus)
Default: No
Slave number of the S5-95F
Default: No
L1"
Default: No
Default: No
Byte Receive"
Default: No
Byte Send"
Default: No
S5-95F on SINEC L1
Value
for Example
PGN 1
SLN 2
SF DB2DW0
(
X
EF DB2DW10
(
X
KBE FY2
KBS FY0
Permissible
Values
PGN x
(x=1 to 30)
SLN x
(x=1 to 30)
SF DBxDWy
=2 to 251; y=0 to
255) or
SF FYz
(z=0 to 255)
EF DBxDWy
=2 to 251; y=0 to
255) or
EF FYz
(z=0 to 255)
KBE MBx
(x=0 to 255)
or
KBE DByDWz*
(y=2 to 251;
z=0 to 255)
KBS MBx
(x=0 to 255)
or
KBS DByDWz*
(y=2 to 251;
z=0 to 255)
13-5