Bank Setting

Bank setting:

Up to four sets of settings can be stored in memory. (Default: bank 0) This is
recommended, for example, when measuring on multi-lot lines.
Procedure for setting up banks
Set to the MENU mode
Bank switching
Various settings
Return to RUN mode
Setting completed
Important
• When connecting two or more Amplifier Units, use the CH1 Amplifier Unit for switching. The
Amplifier Units of CH2 and later are switched together with CH1.
1
Set to the MENU mode
Button
Display
Operation
Hold down for
3 seconds
Press to display.
ZX2 User's Manual
Setting channels used when connecting multiple units
Bank switching: CH1
Bank registration: Each CH
Description of Operation
Hold down the
Lit
three seconds to switch to the
MENU mode.
Press the
button to display
.
Press the
button to set the
display to
to set display of
the detail menu.
Press the
button to apply
the setting.
The following menu settings can be registered to banks:
HIGH threshold
LOW threshold
Response time
Hysteresis width
Measured value display scaling
Pre-scaling display value 1
Post-scaling display value 1
Pre-scaling display value 2
Post-scaling display value 2
Self-trigger level
Display during zero reset
Sensing conditions
when executing smart tuning
Explanation of
Selection Menu
button for
* This step is not required if
detail menu display is
already set to ON in the
MENU mode.
CONTENTS
INTRODUCTION
PREPARATION
FOR

MEASUREMENT

FLOW OF
OPERATION
BASIC
SETUP
MAIN
APPLICATIONS
& SETTING
METHODS
Height
Steps
and
Warpage
Double
Sheet
Detection
Thickness
Positioning
Eccentricity
and Surface
Deflection
DETAILED
SETTINGS
TROUBLE-
SHOOTING
SPECIFI-
CATIONS
INDEX
SETTING
TRANSITION
CHARTS
99
Bank Setting

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents