Error-head
Sensor Head system error.
Error-head
Error-head
Error-head
Because the Sensor Head version is
old, the connected Amplifier Unit
cannot be used.
Error-memory
Amplifier Unit setting memory error.
Error-memory
Amplifier Unit setting memory error.
Error-short
One or all of the judgment outputs are
short-circuited.
Error-system
Amplifier Unit system error.
Tuning-failed
Smart Tuning failed.
(The error output signal is not output.)
ZX2 User's Manual
Error
Countermeasure
• Turn OFF the power supply, check
the Sensor Head connection, and
then turn ON the power supply
again.
• If the above countermeasure does
not solve the problem, the Sensor
Head is malfunctioning. Replace
the Sensor Head.
• Contact the company with which
your company is doing business or
the OMRON sales representative
handling your company.
• Turn OFF the power supply, check
if wiring is connected correctly, and
then turn ON the power supply
again.
• If the above countermeasure does
not solve the problem, the
Amplifier Unit is malfunctioning.
Replace the Amplifier Unit.
• Initialize the settings by holding
down the SET key for at least three
seconds.
• If the above countermeasure does
not solve the problem, the
Amplifier Unit is malfunctioning.
Replace the Amplifier Unit.
• Turn OFF the power supply, check
that the HIGH, PASS, LOW or
error output lines are not short-
circuited, then turn ON the power
supply again.
• Turn OFF the power supply, check
if wiring is connected correctly, and
then turn ON the power supply
again.
• If the above countermeasure does
not solve the problem, the
Amplifier Unit is malfunctioning.
Replace the Amplifier Unit.
• Change the response time setting
to a larger value, and try again.
• Make sure that the distance
between the Sensor and
Workpiece is within the
measurement range, and try again.
Error Messages
CONTENTS
INTRODUCTION
PREPARATION
FOR
MEASUREMENT
FLOW OF
OPERATION
BASIC
SETUP
MAIN
APPLICATIONS
& SETTING
METHODS
Height
Steps
and

Warpage

Double
Sheet
Detection
Thickness
Positioning
Eccentricity
and Surface
Deflection
DETAILED
SETTINGS
TROUBLE-
SHOOTING
SPECIFI-
CATIONS
INDEX
SETTING
TRANSITION
CHARTS
131
131

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents