Lenovo x3300 M4 7382 Installation And Service Manual page 688

Hide thumbs Also See for x3300 M4 7382:
Table of Contents

Advertisement

• 089-801-000 : CPU Stress Test Aborted
CPU Stress Test Aborted. Internal Program Error.
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Turn off and restart the system.
2. Make sure that the DSA Diagnostic code is at the latest level.
3. Run the test again.
4. Check system firmware level and upgrade if necessary. The installed firmware level can be found
in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest
level firmware for this component can be found in reference to this system type at the IBM
Support website.
5. Run the test again.
6. If the system has stopped responding, turn off and restart the system and then run the test again.
7. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
Lenovo Support website
Latest level of DSA
Latest level of BMC/IMM
• 089-802-000 : CPU Stress Test Aborted
CPU Stress Test Aborted. System resource unavailability error.
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Turn off and restart the system.
2. Make sure that the DSA Diagnostic code is at the latest level.
3. Run the test again.
4. Check system firmware level and upgrade if necessary. The installed firmware level can be found
in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
676
System x3300 M4 Installation and Service Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3300 m47382

Table of Contents