Lenovo x3300 M4 7382 Installation And Service Manual page 453

Hide thumbs Also See for x3300 M4 7382:
Table of Contents

Advertisement

5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained service technician only) Remove the affected microprocessor and check the
microprocessor socket pins for any damaged pins. If a damage is found, replace the system
board.
7. (Trained service technician only) If the problem is related to microprocessor socket pins, replace
the system board. One of the DIMMs :
• 806f0313-1701ffff : A software NMI has occurred on system [ComputerSystemElementName]. (NMI
State)
This message is for the use case when an implementation has detected a Software NMI.
May also be shown as 806f03131701ffff or 0x806f03131701ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0228
User Response
1. Check the device driver.
2. Reinstall the device driver.
3. Update all device drivers to the latest level.
4. Update the firmware (UEFI and IMM).
• 806f0323-2101ffff : Power cycle of system [ComputerSystemElementName] initiated by watchdog
[WatchdogElementName]. (IPMI Watchdog)
This message is for the use case when an implementation has detected a Power Cycle by Watchdog
occurred.
May also be shown as 806f03232101ffff or 0x806f03232101ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
Appendix A. Integrated management module II (IMM2) error messages
441