Lenovo x3300 M4 7382 Installation And Service Manual page 233

Hide thumbs Also See for x3300 M4 7382:
Table of Contents

Advertisement

Table 22. Network adapters (continued)
Description
6Gb SAS HBA Controller
Brocade 8Gb FC single-port HBA
Brocade 8Gb FC dual-port HBA
NetXtreme II 1000 express quad-port Ethernet adapter
Intel Ethernet dual-port server adapter I340-T2
Intel Ethernet quad-port server adapter I340-T4
Broadcom NetXtreme II dual-port 10GBaseT adapter
Intel X520-DA2 dual-port 10GbE SFP adapter
Brocade 4Gb FC single-port HBA
Brocade 4Gb FC dual-port HBA
Broadcom NetXtreme I quad-port GbE adapter
Broadcom NetXtreme I dual-port GbE adapter
Emulex 10 GbE virtual fabric adapter III
Emulex 10 GbE virtual fabric adapter III lite
• Depending on your server models, the server comes with an onboard RAID controller which provides
basic RAID levels 0 and 1 functionality. The server supports the following optional RAID adapters that you
can purchase for additional RAID support. For configuration information, see the documentation that
comes with the adapter or the ServeRAID documentation at
Attention: Some cluster solutions require specific code levels or coordinated code updates. If the device
is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before
you update the code.
Attention: Static electricity that is released to internal server components when the server is powered-on
might cause the server to stop, which might result in the loss of data. To avoid this potential problem, always
use an electrostatic-discharge wrist strap or other grounding system when working inside the server with the
power on.
To install an adapter, complete the following steps:
Note: If your adapter was previously configured, back up or record its configuration information, if possible,
before replacing the adapter. See the documentation for your adapter for information and instructions.
1. Read the safety information that begins in "Safety" on page v and "Installation guidelines" on page 169.
2. Turn off the server (see "Turning off the server" on page 24) and all attached peripheral devices.
Disconnect all power cords; then, disconnect all external cables from the server.
3. Carefully turn the server on its side so that it is lying flat, with the cover facing up.
Attention: Do not allow the server to fall over.
4. Unlock and remove the left-side cover (see "Removing the left-side cover" on page 193).
5. Remove the air baffle (see "Removing the air baffle" on page 195).
Network Adapters
http://www.lenovo.com/support
Chapter 6
Option part
number
46M0907
46M6049
46M6050
49Y4220
49Y4230
49Y4240
49Y7910
49Y7960
59Y1987
59Y1993
90Y9352
90Y9370
95Y3762
95Y3768
.
.
Removing and replacing components
CRU part
number
68Y7354
46M6061
46M6062
49Y7949
49Y4232
49Y4242
49Y7912
49Y7962
59Y1992
59Y1998
90Y9355
90Y9373
9573766
95Y3766
221

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3300 m47382

Table of Contents