50
CIM Information
Prefix: PLAT ID: 0522
User Response
1. Check for a server firmware update.
2. Make sure that the installed microprocessors are compatible.
3. Make sure the microprocessor 2 expansion board is installed correctly (see Installing the
microprocessor 2 expansion board).
4. (Trained technician only) Replace microprocessor 2.
5. (Trained technician only) Replace microprocessor 2 expansion board.
• 8007021b-0302ffff : Sensor [SensorElementName] has transitioned to critical from a less severe
state. (CPU 2 QPILinkErr)
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 8007021b0302ffff or 0x8007021b0302ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0522
User Response
1. Check for a server firmware update.
2. Make sure that the installed microprocessors are compatible.
3. Make sure the microprocessor 2 expansion board is installed correctly (see Installing the
microprocessor 2 expansion board).
4. (Trained technician only) Replace microprocessor 2.
5. (Trained technician only) Replace microprocessor 2 expansion board.
• 80070301-0301ffff : Sensor [SensorElementName] has transitioned to non-recoverable from a less
severe state. (CPU 1 OverTemp)
This message is for the use case when an implementation has detected a Sensor transitioned to non-
recoverable from less severe.
May also be shown as 800703010301ffff or 0x800703010301ffff
Severity
Error
Serviceable
Yes
Appendix A. Integrated management module II (IMM2) error messages
369