• 806f000d-040fffff : The Drive [StorageVolumeElementName] has been added. (Drive 15)
This message is for the use case when an implementation has detected a Drive has been Added.
May also be shown as 806f000d040fffff or 0x806f000d040fffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0162
User Response
No action; information only.
• 806f000f-220101ff : The System [ComputerSystemElementName] has detected no memory in the
system. (ABR Status)
This message is for the use case when an implementation has detected that memory was detected in the
system.
May also be shown as 806f000f220101ff or 0x806f000f220101ff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0794
User Response
1. Make sure the server meets the minimum configuration to start (see Power-supply LEDs).
2. Recover the server firmware from the backup page: a. Restart the server. b. At the prompt, press
F3 to recover the firmware.
3. Update the server firmware on the primary page. Important: Some cluster solutions require
specific code levels or coordinated code updates. If the device is part of a cluster solution, verify
that the latest level of code is supported for the cluster solution before you update the code.
4. Remove components one at a time, restarting the server each time, to see if the problem goes
away.
5. If the problem remains, (trained technician only) replace the system board.
Appendix A. Integrated management module II (IMM2) error messages