• Power supply
• Power cord
Note: You must turn on the server for the DC LED on the power supply to be lit.
The following minimum configuration is required for the server to start:
• One microprocessor in microprocessor socket 1
• One 2 GB DIMM (per microprocessor) on the system board
• One power supply
• Power cord
• 2 cooling fans (fan 2 and rear fan)
The following table describes the problems that are indicated by various combinations of the power-supply
LEDs and the power-on LED on the operator information panel and suggested actions to correct the
detected problems.
Power-supply LEDs
Error (!)
AC
DC
On
On
Off
Off
Off
Off
Off
On
Off
On
On
Off
22
System x3300 M4 Installation and Service Guide
Description
Off
Normal operation
Off
No ac power to the
server or a
problem with the
ac power source.
On
Faulty power-
supply
Off
Faulty power-
supply
On
Faulty power-
supply
Off
Power supply not
fully seated, faulty
system board,
faulty power
supply, or system
not power-on
Action
1. Check the ac power to the
server.
2. Make sure that the power
cord is connected to a
functioning power source.
3. Restart the server. If the error
remains, check the power-
supply LEDs.
4. Replace the power-supply.
Replace the power supply.
Replace the power supply.
Replace the power supply.
1. Reseat the power supply.
2. Use the Power Configurator
utility to determine current
system power consumption.
For more information and to
download the utility, go to
http://www-03.ibm.com/
systems/bladecenter/
resources/powerconfig.html
3. For hot-swap power-supply
systems, follow actions listed
in "Power problems" on page
145 and "Solving power
problems" on page 152.
Notes
This is a normal
condition when no ac
power is present.
Typically indicates a
power-supply is not
fully seated.
.