Lenovo x3300 M4 7382 Installation And Service Manual page 412

Hide thumbs Also See for x3300 M4 7382:
Table of Contents

Advertisement

SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0086
User Response
1. Reseat power supply n.
2. If the power-on LED is not lit and the power-supply error LED is lit, replace power supply n.
3. If both the power-on LED and the power-supply error LED are not lit, see Power problems for
more information. (n = power supply number)
• 806f0109-1301ffff : [PowerSupplyElementName] has been Power Cycled. (Host Power)
This message is for the use case when an implementation has detected a Power Unit that has been power
cycled.
May also be shown as 806f01091301ffff or 0x806f01091301ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0108
User Response
No action; information only.
• 806f010c-2001ffff : Uncorrectable error detected for [PhysicalMemoryElementName] on
Subsystem [MemoryElementName]. (DIMM 1)
This message is for the use case when an implementation has detected a Memory uncorrectable error.
May also be shown as 806f010c2001ffff or 0x806f010c2001ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0138
400
System x3300 M4 Installation and Service Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3300 m47382

Table of Contents