Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0224
User Response
1. Reseat the microprocessor, and then restart the server.
2. Replace microprocessor n. (n = microprocessor number)
• 806f0113-0302ffff : A bus timeout has occurred on system [ComputerSystemElementName]. (CPU
2 PECI)
This message is for the use case when an implementation has detected a Bus Timeout.
May also be shown as 806f01130302ffff or 0x806f01130302ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0224
User Response
1. Reseat the microprocessor, and then restart the server.
2. Replace microprocessor n. (n = microprocessor number)
• 806f0123-2101ffff : Reboot of system [ComputerSystemElementName] initiated by
[WatchdogElementName]. (IPMI Watchdog)
This message is for the use case when an implementation has detected a Reboot by a Watchdog
occurred.
May also be shown as 806f01232101ffff or 0x806f01232101ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Appendix A. Integrated management module II (IMM2) error messages
419