What Your Server Offers - Lenovo x3300 M4 7382 Installation And Service Manual

Hide thumbs Also See for x3300 M4 7382:
Table of Contents

Advertisement

The maximum harmonic content of the input voltage waveform will be equal or less than 2%. The
qualification is compliant with EN 61000-3-2.
Information and documentation on the instrumentation set-up and circuits used for electrical testing:
ENERGY STAR Test Method for Computer Servers; ECOVA Generalized Test Protocol for Calculating
the Energy Efficiency of Internal Ac-Dc and Dc-Dc Power Supplies.
Measurement methodology used to determine information in this document:
ENERGY STAR Servers Version 2.0 Program Requirements; ECOVA Generalized Test Protocol for
Calculating the Energy Efficiency of Internal Ac-Dc and Dc-Dc Power Supplies.

What your server offers

The server uses the following features and technologies.
• System Director Active Energy Manager
Systems Director Active Energy Manager
components built into Lenovo systems enabling a cross-platform management solution. This solution
helps customers monitor energy consumption to allow better utilization of available energy resources. The
application software enables customers to trend actual energy consumption and corresponding thermal
loading of Lenovo Systems running in their environment with their applications. For more information,
including the required levels of Systems Director and Active Energy Manager, see the Systems Director
documentation on the Systems Director DVD, or see the
aem/index.html
.
• Dynamic System Analysis (DSA) Preboot
The server comes with the Dynamic System Analysis (DSA) Preboot diagnostic program stored in the
integrated USB memory on the server. DSA Preboot collects and analyzes system information to aid in
diagnosing server problems, as well as offering a rich set of diagnostic tests of the major components of
the server. DSA Preboot collects the following information about the server:
– Drive health information
– Event logs for ServeRAID controllers and service processors
– Hardware inventory, including PCI and USB information
– Light path diagnostics status
– Microprocessor, input/out hub, and UEFI error logs
– Network interfaces and settings
– RAID controller configuration
– Service processor (Integrated Management Module II) status and configuration
– System configuration
– Vital product data, firmware, and UEFI configuration
DSA Preboot also provides diagnostics for the following system components (when they are installed):
– Intel network adapter
2
– IMM i
C bus
– Light path diagnostics panel
– Memory modules
– Microprocessors
– Optical devices (CD or DVD)
– SAS or SATA drives
10
System x3300 M4 Installation and Service Guide
TM
(AEM) will measure, monitor, and manage the energy
http://www-03.ibm.com/systems/software/director/

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3300 m47382

Table of Contents