Omron VARISPEED E7 User Manual page 81

Variable torque frequency inverter
Hide thumbs Also See for VARISPEED E7:
Table of Contents

Advertisement

Parameter
Class
Number
C6-02
d1-01 to
d1-04 and
E1-01
4
E2-01
H4-02
H4-05
L1-01
L3-04
6
4-
Table 4.1 Basic Parameter Settings
Name
Sets the carrier frequency. The factory
Carrier frequency
setting and setting range depends on the
selection
setting of C6-01.
Frequency refer-
ences 1 to 4 and
Sets the required speed references for
jog frequency ref-
multi-step speed operation or jogging.
d1-17
erence
Input voltage set-
Sets the Inverter's nominal input voltage
ting
in volts.
Motor rated cur-
Sets the motor rated current.
rent
Can be used to adjust the analog output
FM and AM ter-
and
when an instrument is connected to the
minal output gain
FM or AM terminal.
Used to enable or disable the motor over-
load protection function.
Motor protection
0: Disabled
selection
1: Protection for general purpose motor
(fan cooled)
If using the dynamic brake option (Brak-
Stall prevention
ing Resistor Units and Braking Units), be
selection during
sure to set parameter L3-04 to 0 (dis-
deceleration
abled).
Description
0 to 200.00 Hz
155 to 255 V
(200 V class)
310 to 510 V
(400 V class)
10% to 200%
of Inverter's
rated current
: Must be set.
: Set as required.
Setting
Factory
Page
Range
Setting
Depends
5-20
0 to F
on setting
6-2
of C6-01.
d1-01 to
d1-04: 0.00
5-21
Hz
6-6
d1-17: 6.00
Hz
200 V
(200 V
class)
5-23
400 V
6-96
(400 V
class)
Setting for
general-
purpose
5-24
motor of
6-32
same
6-95
capacity as
Inverter
H4-02:
0.0 to
100%
5-30
1000.0%
H4-05:
6-64
50%
5-32
0 or 1
1
6-32
5-34
0 to 2
1
6-19