Motor Setup: E2
Param-
eter
Number
Motor rated cur-
E2-01
rent
Motor no-load
E2-03
current
Motor line-to-line
E2-05
resistance
* 1. The setting range is 10% to 200% of the Inverter's rated output current. The value for a 200 V class inverter of 0.4 kW is given.
* 2. The factory setting depends upon the Inverter capacity. The value for a 200 V class inverter of 0.4 kW is given.
* 3. The setting range depends on the inverter capacity. The values for a 200 V class inverter of 0.4 kW are given.
5
24
5-
Name
Description
Sets the motor rated current.
This set value will become the ref-
erence value for motor protection
and torque limits.
This parameter is an input data for
autotuning.
Sets the motor no-load current.
This parameter is automatically set
during autotuning.
Sets the motor phase-to-phase
resistance in Ω units.
This parameter is automatically set
during autotuning.
Change
Setting
Factory
during
Access
Range
Setting
Opera-
Level
tion
0.32 to
1.90 A
6.40
No
Q
*2
*1
0.00 to
*2
No
A
1, 2
*3
1.89
0.000
9.842
to
No
A
65.000
*2
MEMO-
BUS
Page
Register
6-32
30EH
6-95
310H
312H
6-95