Control Panel
This parameter allows you to determine if a Fail to Close report is sent for this area. This
parameter can also be used to determine if a user failed to arm the area before the closing
window expired.
Normal opening and closing reports do not need to be programmed to use this parameter.
An exit delay time must be programmed in Exit Delay Time, page 94.
If Auto Close, page 104 is set to Yes, a report is sent because it occurs when the closing
window stop time occurs.
If Disable O/C in Window, page 103 is set to Yes, Fail to Close report is followed by Closing
Late or Force Close Late report.
RPS Menu Location
Area Wide Parameters > Area/Bell Parameters, Open/Close Options > Fail To Close
4.1.28

Latest Close Time

Default: Disabled
Selections:
Use this parameter to set a latest close time boundary when an open/close window is
assigned to the selected area.
If the Latest Close Time setting is set to a non-zero value, the time of day specified in the
Close Window Start, page 212 parameter cannot be greater than or equal to the Latest Close
Time setting. For example, if the Latest Close Time parameter is set to 17:30, the Close
Window Start parameter cannot be set to 17:30 or higher.
RPS Menu Location
Area Wide Parameters > Area/Bell Parameters, Open/Close Options > Latest Close Time
4.1.29

Restricted O/C

Default: No
Selections:
This parameter determines if opening and closing report activity for this area is restricted.
Was Force Armed and Forced Close events are still sent to the central station if enabled in
routing when force arming the system.
A restricted opening report means the control panel sent an area opening report only when
the area is disarmed after a non-fire/gas alarm.
A restricted closing report means the control panel sent an area closing report only when the
area was All On with controlled points that were faulted during the arming sequence. The
sequence of reports generated by a restricted closing are: Was Force Armed, Forced Point,
Forced Close, then Closing Report.
Opening and Closing reports can be restricted for certain users by configuring the user
authority Restricted Open/Close.
If a passcode is not required for turning the system on, closing reports are always restricted
when A# Restricted O/C is Yes.
Bosch Security Systems, Inc.
No - a Fail to Close report is not sent for this area.
Disabled - RPS sends 0:00 to the control panel.
00:30 to 23:30 - set the time for latest close. Set in 30 minute increments using 01 to 24
to specify the hour.
Midnight - RPS sends 24:00 to the control panel.
Yes - restrict opening and closing reports for this area. Area O/C, page 103 must be set to
Yes to generate restricted opening and closing reports.
No - do not restrict opening and closing reports for this area. Regardless of programming
in Restricted O/C , reports are not restricted in this area when this item is set to No.
Program Entry Guide
Area Wide Parameters | en 105