Duress Enable; Area Type - Bosch B9512G Program Entry Manual

Security system
Hide thumbs Also See for B9512G:
Table of Contents

Advertisement

96
en | Area Wide Parameters
4.1.11

Duress Enable

Default: No
Selections:
This parameter determines if this area allows duress alarms to be generated.
Notice!
To comply with SIA CP-01, set this parameter to Yes.
If [MENU 35] is used to move the keypad display to an area where this parameter is set to No,
a valid duress disarm passcode does not send a duress report. If you set the parameter to No
in a particular area, the passcode you normally enter for Duress is no longer valid in that area.
If this parameter is set to No, and a passcode with the appropriate disarm authority is used to
duress-disarm the area, NO AUTHORITY appears in the keypad display.
RPS Menu Location
Area Wide Parameters > Area/Bell Parameters, Open/Close Options > Duress Enable
Additional resources
Refer to Duress Type, page 74 for an explanation of Duress
4.1.12

Area Type

Default: Regular
Selections: (selections vary depending on the control panel type)
Notice!
Keypad Scope affects master arming. When arming a master area from a keypad with Keypad
Scope set to Panel Wide or Account Wide, all Associate areas enter Exit Delay as soon as the
Master area is armed. If there is a Shared area within the same account, it begins its Exit
Delay after all Associate areas are armed.
Notice!
Using the arming sked requires that you first use an arming sked to arm the Associate areas
before using an arming sked to arm the Master area. Arming Master areas with RPS,
Keyswitch, or Auto Close parameters occurs before all Associate areas are armed.
2017.03 | 09 | F.01U.303.998
Yes. Enable Duress alarm for this area.
No. Disable Duress alarm for this area.
Regular - will arm or disarm as an independent area.
Master - will not allow arming for this area unless all Associate areas with the same A#
Acct Number are exit delay arming or are All On Delay. A Check Area message displays if
the Associate areas have not yet been armed. EXCEPTION: RPS allows Master areas to be
armed without all Associate areas being in the armed state. A Master area can be
disarmed regardless of the armed state of the other areas in the account. Multiple Master
areas can be programmed in a single account.
Associate - will allow arming and disarming regardless of the armed state of the other
areas with the same A# Acct Number . This type of area is used with a Master Area and is
associated by having the same account number. Using the arming Sked requires that you
first use an arming Sked to arm the Associate areas before using an arming Sked to arm
the Master area. Keypads assigned to Associate areas, when used in conjunction with
Shared areas, should have the KP# Scope programmed to encompass the Shared Area.
Program Entry Guide
Control Panel
Bosch Security Systems, Inc.