134 en | Output Parameters
Each area can be assigned a unique output number for each of the events listed in this
section.
Notice!
To comply with UL 864 requirements for Commercial Fire Systems, program this parameter
with a relay.
RPS Menu Location
Output Parameters > Area Wide Outputs > Fire Bell
8.1.3

Reset Sensors

Default: 3
Selections:
This parameter (output C) output de-activates for five seconds when the RESET SENSORS?
function is initiated from the keypad or during a FIRE WALK? test.
The Reset Sensor time converts from the five second default time to the time programmed in
Restart Time (Area parameters section) when a point programmed for Alarm Verify, page 199
(Point Index Section) goes into an alarm event.
When sharing one output to reset sensors in two or more areas, you must program the
parameters below. Failure to do so can cause TROUBLE PT ### for all point types programmed
as Resettable, page 199.
Each area can be assigned a unique output number for each of the events listed in this
section.
RPS Menu Location
Output Parameters > Area Wide outputs > Reset Sensors
8.1.4

Fail to Close/Part On Armed

Default: 0
Selections:
To change between the Fail To Close and Part On output functions described below, configure
the Part On Output, page 81 parameter.
This output activates when the closing window expires for the specified area. It remains
activated until midnight, or until another closing window starts, or the control panel is reset,
whichever occurs first.
Each area can be assigned a unique output number for each of the events listed in this
section.
This output activates when all areas assigned to the same output are armed Part On Instant or
Part On Delayed.
RPS Menu Location
Output Parameters > Area Wide Outputs > Fail to Close/Part On
2017.03 | 09 | F.01U.303.998
B9512G: 0 to 599
B8512G: 0 to 99
Scope, page 111 must include all the areas that are sharing the output.
Reset Sensor(s), page 167 for the user initiating the sensor reset must be enabled in all
the areas that are sharing the output.
Restart Time, page 94 must be the same number of seconds for all the areas that are
sharing the output.
B9512G: 0 to 599
B8512G: 0 to 99
Program Entry Guide