Area Arming Text; Area Name Text; Account Is On Text - Bosch B9512G Program Entry Manual

Security system
Hide thumbs Also See for B9512G:
Table of Contents

Advertisement

108 en | Area Wide Parameters
For example if Area Re-Arm Time is set to four hours (04:00) and the area is disarmed (turned
off) at 1:30 pm, it rearms to All On Delay at 5:30 pm. Any points not ready to arm (faulted) are
force armed.
Notice!
Force Arm / Bypass Max is ignored when re-arming
All points not ready to arm (faulted) are force armed when the area re-arms at the end of Area
Re-Arm Time.
The area automatically re-arms at 11:59 pm regardless of when the Area Re-Arm timer started.
For example, if the Area Re-Arm timer is set to 4 hours (04:00) and the area is disarmed
(turned off) at 10:30 pm, the area rearms to All On Delay at 11:59 pm (1 hour and 29 minutes
after disarm).
Users can use Extend Close time from a system keypad to extend an active Area Re-arm delay
(On/Off Menu > Extend Close time).
Notice!
Configuring Closing Window and Area Re-Arm Time may cause unexpected Area behavior.
When both a Closing Window and Area Re-Arm Time are configured for the same area,
the Closing Window is running simultaneously with the Area Re-arm timer,
and a user uses the Extend Close time from a system keypad,
the control panel extends only the Closing Window, not the Area Re-Arm Time.
RPS Menu Location
Area Wide Parameters > Area/Bell Parameters, Open/Close Options > Area Re-Arm Time
4.2

Area Arming Text

The B9512G supports up to 32 areas. The B8512G supports up to 8 areas.
4.2.1

Area name text

Default: Area # (# = the Area number)
Selections: Up to 32 characters
This parameter sets what is displayed at keypads. This is for informational purposes only.
Enter up to 32 characters of text, numbers and symbols to describe the area.
RPS Menu Location
Area Wide Parameters > Area/Bell Parameters, Open/Close Options > Area Arming Text > Area
Name Text
4.2.2

Account is On text

Default: Blank
Selection: Enter up to 32 characters.
This parameter displays the text to display at the keypad for each area as required.
Notice!
When using a D1255F, D1256F, or D1257F keypad, program this parameter as *Fire System*.
2017.03 | 09 | F.01U.303.998
Keypads display the first 20 characters. If more than 20 characters are used, the area
name text scrolls across the display one time. To scroll the text again, press [ESC].
Spaces before, after and within a string of text are treated as text and are included in the