Table 28: Sample Power Requirements for an SRX5800 Services Gateway with SCB1 and RE1
Chassis Component
Part Number
Base system
SRX5800BASE-HC-AC
High-capacity cooling
SRX5800-HC-FAN
system
SPC - slots 0 through
SPC2
4
See note below.
MPC - slot 5
IOC2 with two MICs
SCB 0 - slot 6
SCB1 with
RE1
SCB 1- slot 7
SCB1
MPC - slot 8
IOC2 with two MICs
SPC - slots 9 through
SPC2
13
See note below.
Total power requirement
Copyright © 2015, Juniper Networks, Inc.
One SRX5K-40GE-SFP I/O card (IOC)
SRX5K-SPC-4-15-320 (SPC2) Services Processing Card
NOTE:
You must have high-capacity power supplies (either AC or DC) and
high-capacity fan trays installed in the services gateway in order to install
and use SPC2. If you do not have high-capacity power supplies and fan
trays installed, the services gateway will log an alarm condition when it
recognizes the SPC.
High-capacity cooling system (upper and lower fan trays)
NOTE:
The high-capacity cooling system satisfies cooling requirements
of SPC2 and must be used for proper cooling.
Calculate the power requirements (usage) as shown in
1.
Table 32 on page
113.
Power Requirement
50 W
320 W * 2 = 640 W
585W * 5 = 2925 W
570 W
150 W
90 W
150 W
570 W
585W * 5 = 2925 W
SRX5800
standard-capacity AC
(not zoned) 8070 W
Chapter 7: Planning and Preparing the Site
Table 28 on page 109
Zone 0 Power
Zone 1 Power
25 W
25 W
320 W
320 W
2925 W
570 W
240 W
150 W
570 W
2925 W
Zone 0 total: 3990 W
Zone 1 total: 4080 W