Table 18: High-Capacity Ac Power Supply Input Mode Switch Settings - Juniper SRX5800 Hardware Manual

Services gateway
Hide thumbs Also See for SRX5800:
Table of Contents

Advertisement

Copyright © 2015, Juniper Networks, Inc.

Table 18: High-Capacity AC Power Supply Input Mode Switch Settings

Mode Switch
Setting
AC Inputs
1
Both AC inlets powered
Only one AC inlet powered
Both AC inlets powered
0
Only one AC inlet powered
NOTE:
We recommend that you set the input mode switch to
two AC input feeds to each high-capacity AC power supply.
WARNING:
To meet safety and electromagnetic interference (EMI)
requirements and to ensure proper operation, the services gateway chassis
must be adequately grounded before power is connected. See
the SRX5800 Services Gateway" on page 220
Chapter 6: Power System Description
Result
DC output of 4100 W
LED lights
DC OK
DC output of 1700 W
LED lights
DC OK
DC output of 4100 W
LED lights
DC OK
DC output disabled
LED unlit
DC OK
1
and connect
"Grounding
for instructions.