management-access-filter
Syntax
management-access-filter
Context
monitor
Description
This command enables the context to monitor management-access filters. These filters are configured
in the config>system>security>mgmt-access-filter context.
port
Syntax
port port-id [port-id...(up to 5 max)] [interval seconds] [repeat repeat] [absolute | rate]
Context
monitor
Description
This command enables port traffic monitoring. The specified port(s) statistical information displays
at the configured interval until the configured count is reached.
The first screen displays the current statistics related to the specified port(s). The subsequent
statistical information listed for each interval is displayed as a delta to the previous display. When the
keyword rate is specified, the "rate per second" for each statistic is displayed instead of the delta.
Monitor commands are similar to show commands but only statistical information displays. Monitor
commands display the selected statistics according to the configured number of times at the interval
specified.
Parameters
port port-id — Specify up to 5 port IDs.
interval seconds — Configures the interval for each display in seconds.
repeat repeat — Configures how many times the command is repeated.
absolute — When the absolute keyword is specified, the raw statistics are displayed, without
rate — When the rate keyword is specified, the rate-per-second for each statistic is displayed
Sample Output
A:ALA-12>monitor# port 1/1/4 interval 3 repeat 3 absolute
===============================================================================
Monitor statistics for Port 1/1/4
===============================================================================
-------------------------------------------------------------------------------
7210 SAS M, T, X, R6 Basic System Configuration Guide
Default
10 seconds
Values
3 — 60
Default
10
Values
1 — 999
processing. No calculations are performed on the delta or rate statistics.
instead of the delta.