System Alarm Contact Commands
alarm-contact-in-power
Syntax
alarm-contact-in-power {on|off}
Context
config>system
Description
This command allows user to enable supply of +24V power to the alarm input. With this feature,
users can use the power supplied through the alarm input pin to supply power to the external sensor
devices, and Equipment cabinet door sensors, and so on connected to the alarm input, instead of using
an external power source for the external sensor devices.
If users want to use an external power source, they disable the supply of power to the alarm input pin
by using this CLI command. By default, power is not supplied to the alarm input pin
Please read the 7210 SAS-T Installation Guide for a description of how to connect the external sensor
devices to use this capability.
NOTE: This CLI command is supported only on the 7210 SAS-T platform.
Default
off
Parameters
on — Turns on power to the alarm input pin.
off — Turns off power to the alarm input pin.
alarm-contact-input
Syntax
alarm-contact-input alarm-contact-input-id
Context
config>system>alarm-contact-input
Description
This command provides the context to configure one of four available alarm contact input pins.
Default
None
Parameters
alarm-contact-input-id — Identifies the alarm contact input pin.
alarm-output-severity
7210 SAS M, T, X, R6 Basic System Configuration Guide
Values
1 — 4 (for 7210 SAS-M and 7210 SAS-T only)
Values
1— 3 (for 7210 SAS-X only)
System Management
Page 421