cflash-cap-warn
Syntax
cflash-cap-warn cflash-id rising-threshold threshold [falling-threshold threshold]
interval seconds [rmon-event-type] [startup-alarm alarm-type]
no cflash-cap-warn cflash-id
Context
config>system>thresholds
Description
This command enables capacity monitoring of the compact flash specified in this command. The
severity level is warning. Both a rising and falling threshold can be specified. The no form of this
command removes the configured compact flash threshold warning.
Parameters
cflash-id — The cflash-id specifies the name of the cflash device to be monitored.
rising-threshold threshold — Specifies a threshold for the sampled statistic. When the current
falling-threshold threshold — Specifies a threshold for the sampled statistic. When the current
interval seconds — Specifies the polling period over which the data is sampled and compared with
rmon-event-type — Specifies the type of notification action to be taken when this event occurs.
7210 SAS M, T, X, R6 Basic System Configuration Guide
cflash-cap-alarm cf1-A: rising-threshold 50000000 falling-threshold 49999900 interval 120
rmon-event-type both start-alarm rising.
Values
cf1:, cf2 (only on 7210 SAS-T), cf1-A:
sampled value is greater than or equal to this threshold, and the value at the last sampling interval
was less than this threshold, a single threshold crossing event will be generated. A single
threshold crossing event will also be generated if the first sample taken is greater than or equal to
this threshold and the associated startup-alarm is equal to rising or either.
After a rising threshold crossing event is generated, another such event will not be generated
until the sampled value falls below this threshold and reaches less than or equal the falling-
threshold value.
Default
0
Values
-2147483648 — 2147483647
sampled value is less than or equal to this threshold, and the value at the last sampling interval
was greater than this threshold, a single threshold crossing event will be generated. A single
threshold crossing event will also be generated if the first sample taken is less than or equal to
this threshold and the associated startup-alarm is equal to falling or either.
After a rising threshold crossing event is generated, another such event will not be generated
until the sampled value raises above this threshold and reaches greater than or equal the rising-
threshold value.
Default
0
Values
-2147483648 — 2147483647
the rising and falling thresholds.
Values
1 — 2147483647