System Alarm Commands
sample-type — Specifies the method of sampling the selected variable and calculating the value to
startup-alarm alarm-type — Specifies the alarm that may be sent when this alarm is first created.
rising-event rmon-event-id — The identifier of the the rmon>event that specifies the action to be
rising-threshold threshold — Specifies a threshold for the sampled statistic. When the current
falling-event rmon-event-id — The identifier of the rmon>event that specifies the action to be taken
Page 360
Guide
be compared against the thresholds.
Default
Absolute
Values
absolute — Specifies that the value of the selected variable will be compared
directly with the thresholds at the end of the sampling interval.
delta — Specifies that the value of the selected variable at the last sample will be
subtracted from the current value, and the difference compared with the thresholds.
If the first sample is greater than or equal to the rising threshold value and 'startup-alarm' is
equal to 'rising' or 'either', then a single rising threshold crossing event is generated.
If the first sample is less than or equal to the falling threshold value and 'startup-alarm' is equal
to 'falling' or 'either', a single falling threshold crossing event is generated.
Default
either
Values
rising, falling, either
taken when a rising threshold crossing event occurs.
If there is no corresponding 'event' configured for the specified rmon-event-id, then no
association exists and no action is taken.
If the 'rising-event rmon-event-id' has a value of zero (0), no associated event exists.
If a 'rising event rmon-event' is configured, the CLI requires a 'rising-threshold' to also be
configured.
Default
0
Values
0 — 65535
sampled value is greater than or equal to this threshold, and the value at the last sampling interval
was less than this threshold, a single threshold crossing event will be generated. A single
threshold crossing event will also be generated if the first sample taken is greater than or equal to
this threshold and the associated startup-alarm is equal to rising or either.
After a rising threshold crossing event is generated, another such event will not be generated
until the sampled value falls below this threshold and reaches less than or equal the 'falling-
threshold' value.
Default
0
Values
-2147483648 — 2147483647
when a falling threshold crossing event occurs. If there is no corresponding event configured for
the specified rmon-event-id, then no association exists and no action is taken. If the falling-event
has a value of zero (0), no associated event exists.
If a 'falling event' is configured, the CLI requires a 'falling-threshold to also be configured.
Default
0
Values
-2147483648 — 2147483647