Intel iAPX 86 User Manual page 193

Table of Contents

Advertisement

LOC86 Controls and Error Messages
iAPX 86,88 Family Utilities
G-24
WARNING 52:
REFERENCED LOCATION OUTSIDE 64K FRAME OF
REFERENCE
MODU LE:
module name
REF ERE NeE 0 L 0 CAT ION: 20-bit address
F RAM E 0 F REF ERE NeE: 20-bit address
Meaning
The target of a self-relative reference lies outside of the 64K frame of reference of
the jump or call. This error occurs while locatiing the module containing the target of
a self-relative instruction.
Cause
This error occurs as a result of misuse of the ORDER or ADDRESSES control.
Effect
LOC86 continues processing. The print file is valid, but the object file with respect
to the module containing the self-relative reference is not executable.
User Action
Examine the locate map and reinvoke LOC86 modifying your ORDER and
ADDRESSES control to correct the error.
WARNING 53:
CANNOT ALLOCATE CLASS AT SPECIFIED ADDRESS
ADD RES S:
20-bit address
C LA S S: class name
Meaning
The specified class cannot be located at the address requested. This is the result of a
conflict with another address assignment, or an absolute segment, or an address less
than 200H.
Effect
LOC86 assigns the class to the nearest address that will not cause conflict. LOC86
continues processing, and both the print and object file are valid.
User Action
If the alternate address suits your purpose, then no action is necessary. Otherwise,
examine the locate map and modify your invocation line.

Advertisement