iAPX 86,88 Family Utilities
LINK86 Controls and Error Messages
ERROR 23:
BAD OBJECT FILE
F I L E:
pathname
MOD U L E:
module name
Meaning
LINK86 has discovered an inconsistency in the fields of a record in the specified
input file.
Cause
This could be an error by the translator or a data transmission error.
Effect
LINK86 immediately terminates processing and closes all open files. The contents of
the print file and the object file are undefined.
User Action
Retranslate the source file. If the problem persists contact Intel.
WARNING 24:
CANNOT FIND MODULE
F I L E:
pathname
MOD U L E:
module name
Meaning
The specified module cannot be found in the specified library file.
Effect
LINK86 continues processing as if the specified module was not in the list.
User Action
If the module is important, you can link it into the output object file later.
WARNING 25:
EXTRA START ADDRESS IGNORED
F I L E:
pathname
MO D U L E:
module name
Meaning
LINK86 has encountered a start address in more than one module.
Cause
This will occur any time you specify more than one main module in the input list.
Effect
LINK86 uses the start address encountered earlier and ignores the start address in
the specified module. LINK86 continues processing with no other side effects.
User Action
None, if the start address in the specified module was intended to be ignored.