LINK86 Controls and Error Messages
iAPX 86,88 Family Utilities
0-28
WARNING 71:
TOO MANY MAIN MODULES IN INPUT
F I L E:
pathname
MO 0 U L E:
module name
Meaning
LINK86 discovered two or more main modules (modules with start addresses) in the
input list.
Cause
The input list contains too many main modules.
Effect
LINK86 uses the start address of the first main module it reads and ignores the
others. The object code will be valid.
User Action
Ensure that the LINK86 interpretation is suitable to your objectives. If not, modify
the input list, and reinvoke LINK86.
WARNING 72:
REGISTER INITIALIZATION CODE EXISTS, NEW
INITIALIZATION IGNORED
F I L E:
path name
MODULE:
modulename
Meaning
Two or more initialization codes for 8086 registers were encountered in the input
list.
Cause
This condition resulted from a translation or linkage problem.
Effect
LINK86 uses the first initialization code and ignores the others. The object code will
be valid.
User Action
If retranslating or relinking does not correct the error, contact Intel.
WARNING 73:
INITCODE CONTROL INEFFECTIVE WITH OVERLAYS
Meaning
Both INITCODE and OVERLAY controls wee specified.
Effect
The INITCODE control is ignored. The object code will be valid.
User Action
Reinvoke LINK86, using the INITCODE control. In a second invocation, specify
the OVERLAY control.