Intel iAPX 86 User Manual page 135

Table of Contents

Advertisement

LINK86 Controls and Error Messages
iAPX 86,88 Family Utilities
0-14
WARNING 32:
EXTRA REGISTER INITIALIZATION RECORD IGNORED
F I L E:
pathname
MOD U L E:
module name
Cause
You have included two main modules in your input list.
Effect
LINK86 uses the first register initialization record and ignores the second. Process-
ing continues.
User Action
If the register initialization information in the specified file and module should be
used, then modify your input list; otherwise, no user action is necessary.
ERROR 33:
ILLEGAL USE OF OVERLAY CONTROL
F I L E:
pathname
MO D U L E:
module name
Meaning
LINK86 has found an overlay definition in the specifed file and module, while pro-
cessing input modules for an overlay.
Effect
LINK86 immediately terminates processing; all open files are closed. The contents
of the print and object files are undefined.
User Action
Remove the specified file from the input list and relink.
ERROR 34:
TOO MANY OVERLAYS IN INPUT FILE
F I L E:
pathname
MOD U L E:
module name
Meaning
The specified file and module above contains more than one overlay definition.
Effect
LINK86 immediately terminates processing; all open files are closed. The contents
of the print and object files are undefined.
User Action
Remove the specified file from the input list and relink.