iAPX 86,88 Family Utilities
LINK86 Controls and Error Messages
WARNING 29:
GROUP HAS BAD EXTERNAL REFERENCE
G R 0 UP:
group name
S E G MEN T:
segment name
Meaning
This error occurs if the public symbol corresponding to an external reference has
been specified by its absolute address, and the address does not reside in any
segment.
Effect
LINK86 continues processing and the print and object files will be valid except the
external reference has not been properly resolved.
User Action
Either remove the reference to the public symbol or do not allow the symbol to be
absolute.
ERROR 30:
LIBRARY IS NOT ALLOWED WITH PUBLICSONLY CONTROL
F I L E:
pathname
Meaning
The specified file is a library and libraries are not allowed in a PUBLICSONL Y
control.
Effect
LINK86 immediately terminates processing and closes all open files. The contents of
the print file and the object file are undefined.
User Action
Remove library file from PUBLICSONL Y argument list and reinvoke LINK86.
WARNING
31:
REFERENCED LOCATION OFFSET UNDERFLOW
F I L E:
pathname
MO 0 U L E:
module name
Meaning
While computing the offset for an 8089 self relative reference, LINK86 had a
negative result.
Cause
Either with the ORDER control or the order of files in the input list, the reference
was separated from its target, or the 8089 segment is too large.
Effect
LINK86 continues processing; however, the nnvalid offset computation is used.
User Action
Examine the ORDER control in the invocation line and modify its arguments.
Reinvoke LINK86 carefully.
0-13