LOC86 Controls and Error Messages
iAPX 86,88 Family Utilities
G-22
ERROR 48:
INVALID COMMAND LINE
Meaning
LOC86 has encountered an end-of-file or an 1/0 error while reading the invocation
line.
Cause
You probably terminated the invocation line in the middle of a control argument.
Most likely you forgot to type the ampersand before you typed the carriage return.
Effect
LOC86 immediately terminates processing; all open files are closed. The contents of
the print and object files are undefined.
User Action
Examine the invocation line and reinvoke LOC86 correctly.
WARNING 49:
SEGMENT AlIGNMENT NOT COMPATIBLE WITH
ASSIGNED ADDRESS
S E G MEN T:
segment name
Meaning
The alignment attribute does not agree with the address specified in the
ADDRESSES control.
Effect
LOC86 ignores the address assignment and treats the segment as any other
relocatable segment.
User Action
If the address that LOC86 assigns is satisfactory, then no action is necessary. Other-
wise, examine the print file and assign an address that will agree with the alignment
attribute.