Intel iAPX 86 User Manual page 178

Table of Contents

Advertisement

iAPX 86,88 Family Utilities
LOC86 Controls and Error Messages
WARNING 16:
LOCAL SYMBOL NOT ADDRESSABLE
N
AM
E:
local symbol name
Meaning
The specified symbol is more than 64K from its base. This error occurs when the seg-
ment containing the local symbol is not completely contained within the 64K
physical segment defined by the symbol's base.
Effect
LOC86 continues processing. The object file will be executable. However, any
attempt to access the specified symbol will not produce the desired results. Debug
symbols with this attribute will not be added to the object file.
User Action
Change the ORDER or ADDRESSES control so that the segment containing the
local symbol will be within range of the symbol's base.
WARNING
17:
LINE NUMBER NOT ADDRESSABLE
N
AM E:
line number
Meaning
The specified line is more than 64K from its base. This error occurs when the seg-
ment containing the line number is not completely contained within the 64K physical
segment defined by the line's base.
Effect
LOC86 continues processing. The object file will be executable. However, any
attempt to access the specified line number will not produce the desired results.
Debug symbols with this attribute will not be added to the object file.
User Action
Change the ORDER or ADDRESSES control so that the segment containing the line
number will be within range of the line's base.