LINK86 Controls and Error Messages
iAPX 86,88 Family Utilities
D-16
ERROR 38:
INVALID OVERLAPPING GROUPS
F I L E:
pathname
MO
D U L E: module name
S E G MEN T:
segment name
GROUP:
group name
Meaning
While binding the input list LINK86 found a segment that was defined to be within
two groups.
Effect
LINK86 immediately terminates processing; all open files are closed. The contents
of the print and object files are undefined.
User Action
Either modify the source to remove the segment from one of the groups or do not
link with the BIND control.
ERROR 39:
SPECIFIED GROUP NOT FOUND IN INPUT MODULE
G ROU P:
group name
Cause
Often this is the result of a typographical error i.n the invocation line.
Effect
LINK86 immediately terminates processing; all open files are closed. The contents
of the print and object files are undefined.
User Action
Correct the invocation line and relink.
ERROR 40:
SPECIFIED SEGMENT NOT FOUND IN THE GROUP
S E G MEN T:
segment name
G R 0
UP:
group name
Cause
Usually this is the result of a typographical error in the ORDER control.
Effect
LINK86 immediately terminates processing; all open files are closed. The contents
of the print and object files are undefined.
User Action
Correct the invocation line and relink.